P2791 Gate Select Direction Circuit Low
What it means
The computer is watching the gate select direction circuit and is reading a voltage that is lower than it should be, which often means a short to ground or a failed part. On automated manual transmissions, this actuator moves the gear selector side to side between gear lanes.
Can I keep driving?
If the check engine light flashes, the engine runs rough, overheats, loses power or stalls, pull over when it is safe and get help. Otherwise get it checked in the next few days and drive gently until then.
What to test before replacing parts
A shop should confirm the fault with a scan tool and a few tests before replacing parts. The code points to where to test, not to a confirmed failed part.
- Inspect the wiring in the gate select direction circuit for rubbed-through insulation touching metal
- Check the wiring for a short to ground with a meter
- Clear the code and see if it returns right away
Signs you may notice
- Check engine or transmission light on
- Gear changes may fail or be slow
- Transmission may not select a gear
Possible causes
Most likely first. Directions for testing, not confirmed failures.
- CommonControl wire to the gate select actuator shorted to ground
- CommonFailed gate select actuator
- PossibleCorroded or loose connector
- PossibleControl module fault (rare)
Typical repair once the cause is confirmed
Fix any shorted wiring first; if the wiring tests good, replace the gate select actuator.
Common questions
What does P2791 mean?
The computer is watching the gate select direction circuit and is reading a voltage that is lower than it should be, which often means a short to ground or a failed part. On automated manual transmissions, this actuator moves the gear selector side to side between gear lanes.
Can I drive with code P2791?
If the check engine light flashes, the engine runs rough, overheats, loses power or stalls, pull over when it is safe and get help. Otherwise get it checked in the next few days and drive gently until then.
What causes P2791?
Common possibilities to test include: control wire to the gate select actuator shorted to ground; failed gate select actuator; corroded or loose connector; control module fault (rare). A shop should confirm the cause before replacing parts.