P266E "A" Rocker Arm Actuator Position Sensor Circuit Intermittent/Erratic (Bank 2)

How urgent? Book a check when convenient

What it means

The computer is watching the "A" rocker arm position sensor (bank 2) and is seeing a signal that cuts in and out. This sensor tells the computer which valve lift mode the rocker arms are actually in.

Can I keep driving?

Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.

What to test before replacing parts

A shop should confirm the fault with a scan tool and a few tests before replacing parts. The code points to where to test, not to a confirmed failed part.

  1. Wiggle the wiring for the "A" rocker arm position sensor (bank 2) with the engine running while watching live data
  2. Check connector pins for corrosion or spread terminals
  3. Note when it happens (hot, cold, bumps) to narrow it down

Signs you may notice

  • Check engine light on
  • Variable valve lift may be disabled
  • Possible loss of power at higher rpm

Possible causes

Most likely first. Directions for testing, not confirmed failures.

  • CommonLoose connector or chafed wire that loses contact over bumps
  • CommonRocker arm actuator position sensor failing on and off
  • PossibleCorrosion inside the connector
  • PossiblePoor ground connection

Typical repair once the cause is confirmed

Repair the loose or corroded connection; replace the rocker arm actuator position sensor if the wiring is solid.

Walk through it step by step: Check engine light on →

Common questions

What does P266E mean?

The computer is watching the "A" rocker arm position sensor (bank 2) and is seeing a signal that cuts in and out. This sensor tells the computer which valve lift mode the rocker arms are actually in.

Can I drive with code P266E?

Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.

What causes P266E?

Common possibilities to test include: loose connector or chafed wire that loses contact over bumps; rocker arm actuator position sensor failing on and off; corrosion inside the connector; poor ground connection. A shop should confirm the cause before replacing parts.