P2675 Air Cleaner Inlet Control Circuit/Open
What it means
The computer is watching the air cleaner inlet control circuit and sees what looks like a broken or disconnected circuit. Some engines use a flap at the air filter box to switch between cold and warm air or to quiet the intake.
Can I keep driving?
Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.
What to test before replacing parts
A shop should confirm the fault with a scan tool and a few tests before replacing parts. The code points to where to test, not to a confirmed failed part.
- Look over the connector and wiring for the air cleaner inlet control circuit, checking for damage, corrosion or a loose fit
- Check power, ground and resistance of the part with a meter
- Clear the code and see if it comes back
Signs you may notice
- Check engine light on
- Usually little change in how the car drives
Possible causes
Most likely first. Directions for testing, not confirmed failures.
- CommonUnplugged, loose or corroded connector at the air intake flap actuator
- CommonBroken or chafed wire in the air cleaner inlet control circuit
- CommonFailed air intake flap actuator
- PossibleBlown fuse or failed relay feeding the circuit
- PossibleControl module fault (rare)
Typical repair once the cause is confirmed
Repair the wiring or connector if it is damaged; otherwise replace the air intake flap actuator.
Common questions
What does P2675 mean?
The computer is watching the air cleaner inlet control circuit and sees what looks like a broken or disconnected circuit. Some engines use a flap at the air filter box to switch between cold and warm air or to quiet the intake.
Can I drive with code P2675?
Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.
What causes P2675?
Common possibilities to test include: unplugged, loose or corroded connector at the air intake flap actuator; broken or chafed wire in the air cleaner inlet control circuit; failed air intake flap actuator; blown fuse or failed relay feeding the circuit. A shop should confirm the cause before replacing parts.