P2406 Evaporative Emission System Leak Detection Pump Sense Circuit High
What it means
The signal from the EVAP leak detection pump sense circuit is higher than the computer expects. This sensor reports back to the computer whether the leak detection pump is working. An open (broken) wire, a bad ground or a failed sensor is the usual reason.
Can I keep driving?
Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.
What to test before replacing parts
A shop should confirm the fault with a scan tool and a few tests before replacing parts. The code points to where to test, not to a confirmed failed part.
- Make sure the leak detection pump connector is fully plugged in and clean
- Check the sensor ground and signal wire for an open circuit
Signs you may notice
- Check engine light on
- Usually no change in how the car drives
- May fail an emissions inspection
Possible causes
Most likely first. Directions for testing, not confirmed failures.
- CommonOpen or broken signal or ground wire
- CommonUnplugged or corroded connector
- PossibleFailed EVAP leak detection pump
- PossibleWire shorted to a power source
Typical repair once the cause is confirmed
Repair any damaged wiring or connector first; if the circuit tests good, replace the EVAP leak detection pump.
Where it shows up
- Leak detection pumps like this are used on many Chrysler, Dodge and Jeep vehicles
Common questions
What does P2406 mean?
The signal from the EVAP leak detection pump sense circuit is higher than the computer expects. This sensor reports back to the computer whether the leak detection pump is working. An open (broken) wire, a bad ground or a failed sensor is the usual reason.
Can I drive with code P2406?
Usually you can keep driving while you book a check. If other warning lights come on, or the car starts running or shifting differently, get it checked sooner.
What causes P2406?
Common possibilities to test include: open or broken signal or ground wire; unplugged or corroded connector; failed evap leak detection pump; wire shorted to a power source. A shop should confirm the cause before replacing parts.