P0880 TCM Power Input Signal
What it means
The computer found an electrical problem in the circuit for the transmission computer (TCM) power input, which supplies the voltage the transmission computer needs to run.
Can I keep driving?
If the check engine light flashes, the engine runs rough, overheats, loses power or stalls, pull over when it is safe and get help. Otherwise get it checked in the next few days and drive gently until then.
What to test before replacing parts
A shop should confirm the fault with a scan tool and a few tests before replacing parts. The code points to where to test, not to a confirmed failed part.
- Look over the wiring and connector at the TCM power feed for damage, rubbing or corrosion
- Check related fuses, power and ground with a meter
- Test the TCM power feed against the factory specification before replacing it
Signs you may notice
- Check engine light on
- Transmission may be stuck in one gear (limp mode)
- Harsh shifts or no upshifts
Possible causes
Most likely first. Directions for testing, not confirmed failures.
- CommonFailed transmission control module
- CommonWeak battery, bad battery terminals or charging problem
- CommonBroken or damaged wiring to the TCM power feed
- CommonLoose, corroded or water-damaged connector
- PossibleBlown fuse or missing power or ground
- PossibleFaulty transmission or engine computer (rare)
Typical repair once the cause is confirmed
Repair any wiring or connector fault found; if the circuit tests good, replace the TCM power feed.
Common questions
What does P0880 mean?
The computer found an electrical problem in the circuit for the transmission computer (TCM) power input, which supplies the voltage the transmission computer needs to run.
Can I drive with code P0880?
If the check engine light flashes, the engine runs rough, overheats, loses power or stalls, pull over when it is safe and get help. Otherwise get it checked in the next few days and drive gently until then.
What causes P0880?
Common possibilities to test include: failed transmission control module; weak battery, bad battery terminals or charging problem; broken or damaged wiring to the tcm power feed; loose, corroded or water-damaged connector. A shop should confirm the cause before replacing parts.